RCDs that don't trip correctly
An RCD can look correctly fitted yet fail to trip within the required time, leaving a shock risk undetected until tested.

Whether it's a single circuit, a new installation, or a full periodic check, testing tells you what's actually happening inside the wiring, carried out with calibrated equipment and reported clearly.
Rated 5.0 on Google · 12+ years in the trade · NAPIT registered
City & Guilds 2391-52
Qualified specifically in inspection and testing
NAPIT registered
Testing and certification to current wiring regulations
£5m / £10m cover
Public and employer's liability insurance in place
5.0 on Google
Rated by clients across South Hampshire
12+ years in the trade
Founded 2021 by Director Andrew Hardiman
Overview
Testing and inspection is the process of checking an electrical installation, or a specific part of it, against current wiring regulations using both a visual check and instrument testing. It sits behind almost every other piece of electrical work: new circuits get tested before being signed off, existing installations get periodically inspected, and specific circuits get tested when something needs confirming.
It's needed after any new installation or alteration, as part of a periodic check on an existing property, when a fault is suspected but not yet confirmed, or when a landlord, business, or homeowner needs documented evidence that an installation meets current standards. It differs from an EICR in scope: testing and inspection can be a targeted check on part of an installation, whereas an EICR is a full condition report, but both rely on the same underlying test procedures.
The value of testing lies in what it reveals that a visual check alone can't: insulation resistance, loop impedance, RCD trip times, and continuity of protective conductors are all things you can't see by looking, but they determine whether the installation will actually protect people and property under fault conditions.
Homeowners, landlords, and businesses needing confirmation that a circuit or installation meets current standards.
After new work, at periodic intervals, when investigating a suspected issue, or for compliance evidence.
Test results and, where appropriate, a certificate, EIC, EICR, or minor works, matching the scope of work.
Instrument testing catches faults that are invisible to a visual inspection alone.
What happens if it is left
A visual inspection tells you a lot, but several of the most important safety measures in an installation can only be confirmed by testing with calibrated instruments.
An RCD can look correctly fitted yet fail to trip within the required time, leaving a shock risk undetected until tested.
If this value is too high, a fault won't clear quickly enough to protect against shock or fire.
Degraded cable insulation can allow current to leak between conductors or to earth without any visible sign.
Reversed polarity on a circuit can leave supposedly isolated parts of the circuit live even when a switch is off.
Our process
The scope varies by job, but the underlying method is consistent and thorough.
We agree whether it's a single circuit, a new installation, or a wider periodic check, and what certificate or record is needed.
We check accessible wiring, connections, and protective devices for condition and compliance.
With the supply isolated, we test continuity, insulation resistance, and polarity.
With the supply restored, we test earth fault loop impedance and RCD operation under load.
Results are recorded and the appropriate certificate, EIC, EICR, or minor works, issued, with building control notified directly where the work is notifiable.
What you get
We can often test a single circuit or small installation in one visit.
Instrument testing confirms protective measures are actually working, not just present.
Catching insulation or connection issues early prevents them developing into bigger faults.
Testing is priced individually once the scope is agreed, with a written quote provided upfront.
Calibrated equipment and a consistent method give results you can rely on.
Documented results and the right certificate give you evidence the installation meets current standards.
In detail
Dead testing is carried out with the circuit isolated from the supply and covers continuity of protective conductors, insulation resistance between live conductors and earth, and polarity, confirming conductors are connected the right way round. These tests have to be done with the supply off, because they'd give false or dangerous results otherwise.
Live testing follows once the supply is safely restored, and covers earth fault loop impedance at relevant points and RCD operation, including trip times under test current. Together, dead and live testing build a complete picture of whether the circuit will behave safely under both normal and fault conditions.
Accurate results depend on properly calibrated test instruments; equipment drifts out of calibration over time and use, so it needs regular checking against a known standard. We use instruments appropriate to each test being carried out, since insulation resistance testing, loop impedance testing, and RCD testing all use different measurement principles and equipment settings.
Testing on a new installation or alteration confirms the work has been done correctly before it's signed off with an EIC or minor works certificate, and it's carried out as a matter of course on every job we complete, not as an optional extra. Periodic testing, by contrast, checks how an existing installation has held up over time and is usually carried out as part of a wider EICR rather than in isolation, though targeted circuit testing on request is available where a specific concern has been raised.
Domestic testing typically covers a single consumer unit and its circuits, whereas commercial premises may have multiple distribution boards and a wider range of circuit types, meaning the time and approach needed are assessed on site. In both settings, results are documented and the correct certificate issued to match the work carried out.
Recent work
Scroll across to see more of our completed work.







Common questions
It's priced individually depending on the scope: a single circuit test is a different job to a full periodic inspection, and we confirm everything with a written quote first.
A single circuit can often be tested in a short visit, while a wider periodic check takes longer; we'll give you a realistic estimate once we know the scope.
We carry out a visual inspection, then dead testing with the circuit isolated, followed by live testing with the supply restored, before documenting the results.
Depending on the job, you'll receive an EIC for new work, an EICR for a full condition check, or a minor works certificate for smaller alterations.
New work is tested as part of the job itself; existing installations are typically checked periodically, commonly every few years, depending on property type and use.
We work Monday to Friday, 8am to 5pm, call 07730 498814 or send us the details online.
Yes, as well as Locks Heath, we cover Warsash, Hedge End, Southampton, Fareham, Titchfield, Park Gate and Whiteley.
Yes, targeted testing on a specific circuit is possible where that's all that's needed, we'll agree the scope with you before booking anything in.